Sale
Automatic Surface Tensiometer, DyneMaster DY-700
High-end surface tensiometer that performs measuring dynamic contact angle and powder contact angle, lamella length and liquid density in addition to surface/interfacial tension.

Features:
◆ Fully automatic operation by single command button
◆ Built-in stirrer functions in the stage
◆ Dynamic contact angle (advancing/receding angle) measurement by Wilhelmy method (Option of DY-700)
◆ Powder contact angle measurement to evaluate wetting phenomena of powder samples (Option of DY-700/500)
◆ Lamella length measurement
◆ Liquid density measurement by pycnometer

Typical applications:
• Dynamic contact angle for evaluating coating properties
• Powder contact angle for evaluating wettability, dispersiveness of powder sample
• Lamella length for evaluating foaming stability of coating agents

System Includes:
Main body built-in thermometer, jacket type stage, magnetic stirrer and built-in calibration system with Platinum plates (x2), Glass lab dishes for surface tension (x2), built in Level, Alcohol lamp, Forceps, and Operation manual.

Software Included:
• Main DYNALYZER Software for performing all basic operations including surface and interfacial tension tests.
• DYNALYZER add-in Powder measurement software
• DYNALYZER add-in Dynamic contact angle measurement software

Specifications:
• Measurement methods: Surface/Interfacial tension, Dynamic contact angle, Powder contact angle & wetting speed, Lamella length measurement, Liquid density measurement (Pycnometer)
• Measurement range of S.T.: 0~100 mN/m (balance capacity & displaying range: 0~1000mN/m
• Measurement accuracy: 0.02 mN/m
• Resolution: 0.01 mN/m
• Stage speed, stroke: 0.002~50 mm/s, 50mm
• Standard measurement unit: platinum plate
• Optional measurement unit & kit: Platinum DuNouy Ring, Density measurement kit, Dynamic contact angle measurement kit, Powder contact angle measurement kit
• Measurement temperature: Ambient ~ 150 degree C (Heater type), 10~70 degree C (jacket type)
• External Dimensions: 295(W) x 415(D) x452(H) mm
• Weight: about 23kg
• Electric power: AC100-240~50/60Hz
51,850.00 51850.0 USD
Sale
Automatic Surface Tensiometer, DyneMaster DY-500
DY-500 DyneMaster Automatic Tensiometer
High-end surface tensiometers that perform measuring dynamic contact angle and powder contact angle, lamella length and liquid density in addition to surface/interfacial tension (Wilhelmy plate or DuNouy Ring).

Features:
◆ Fully automatic operation by single command button.
◆ Built-in stirrer functions in the sample stage.
◆ Dynamic contact angle (advancing/receding angle) measurement by Wilhelmy method (Option of DY-700)
◆ Powder contact angle measurement to evaluate wetting phenomena of powder samples (Option of DY-700/500)
◆ Automatic Critical Micelle Concentration (CMC) of surface tension (Option of DY-700/500)
◆ Built-in surface thermometer (for heated/chilled samples requires electronic heater option or heater/chill bath option)
◆ Lamella length measurement
◆ Liquid density measurement by pycnometer

Measurement methods:
• Surface/interfacial tension
• Powder contact angle & wetting speed
• Lamella length measurement,
• Liquid density measurement (Pycnometer)

Specifications:
• Measurement range of S.T.: 0~100 mN/m *Balance capacity & displaying range: 0~1000mN/m
• Measurement accuracy*: 0.2 mN/m
• Resolution: 0.01 mN/m
• Stage speed, stroke: 0.002~50 mm/s, 50mm
• Standard measurement unit: Platinum plate or Platinum DuNouy Ring
• Optional measurement unit & kit: Platinum ring, Density measurement kit, Dynamic contact angle measurement kit, Powder contact angle measurement kit, CMC Kit
• Measurement temperature: Ambient~150°C (Heater type), 10~70°C (Jacket type)
• External dimensions: 295(W) x 415(D) x 452(H)mm
• Weight: About 20kg
• Electric power: AC100-240~50/60Hz
40,516.00 40516.0 USD
Sale
DSR-500 CP 4000 Plus Rheometer Peltier Air-Air (10-70C)
DSR-500 CP 4000 Rheometer with Peltier Air-Air Temperature Control (10-70C)
17,733.00 17733.0 USD
Sale
Phoenix Smart (A)
Drop shape image analysis contact angle. Sessile drop method. Portable type, equivalent limitless sample size.
Manual, Semi-Auto, Automatic drop control system.
- Max sample size: Equivalent with limitless
- USB 2.0 type Digital CCD camera, Frame rate: 70 frame/sec
- 640x 480 Pixel resolution
- Light source: LED
- Drop position checking window
- Automatic one button capture function
- Able to touch to surface by manual control
- Contact angle measure range: 2-180 degree, ±0.1deg Accuracy
- Surfaceware9 Software for static and dynamic contact angle & Surface energy, Surface tension by Pendent drop method, D-base, Data comparing, exact drop volume calculator function, Auto avoid image noise of measuring
- Able to measuring time set for same time base condition
- Advanced “One drop” function - Drop volume control by software
- Unlimited repeat drop and measure function
- Analyzed data export to Excel, etc
- Standard supplied accessories : Syringe (3ml:10ea), Needle (30G, 27G, 22G:5/each), Manual, Calibration images(30, 120±0.5degree)
- Connect to Desktop PC or Laptop (Windows 7/8/10)
Device dimensions: 91mm(D) x 80mm(W) x 159mm(H)
16,167.00 16167.0 USD
Sale
Automatic Surface Tensiometer, DyneMaster DY-300
This instrument is specified for determining interfacial tension of oil against water by the ring method in ASTM Method D971 and solutionsof surface-active agents in ASTM Method D1331. It is also specified for testing synthetic rubber lattices in ASTM Method D1417 and determing the surface tension of industrial water and industrial wastewater in ASTM Method D1590 (To name a few).

Main unit (laptop PC not included), software provided on CD, Platinum plates or DuNouy Ring (choose 2), Glass lab dishes for surface tension (x2), Calibration weights (200mg x2), built in Level, Alcohol lamp, Forceps, and operation manual.

Features:
◆ ­Fully automatic operation by single command button
◆ For QC use, repetition of measurement can be preset
­◆ For surface solutions, graph of variations over time can be plotted
­◆ For R&D use, functions of graph overwriting and data converting to a spreadsheet can be prepared
­◆ Measurements of lamella length and liquid density are available in addition to surface/interfacial tension

Screens:
• ­Surface Tension (static mode)
­• Surface Tension (dynamic variations over time)
­• Surface Tension (high viscous material)
­• Lamella Length

Applications:
• ­Surface Tension: evaluating detergency of detergents, wettability of coating agents
­• Interfacial Tension: evaluating emulsification property of water/oil
­• Lamella Length: evaluating foaming stability of coating agents
• Liquid Density: measuring density of liquids

Specifications:
• Measurement Method: Wilhelmy Plate method and or DuNouy Ring method
­• Measurement Range: 0~100 mN/m *Balance capacity and displaying range 0~1000 mN/m
• ­Measurement Accuracy: 0.2 mN/m
­• Resolution: 0.01 mN/m
• ­Stage Speed: 0.1~1 mm/s
­• Measurement Temperature: Ambient~150 degrees C (Heater type stage system)10~70 degrees C (Jacket type stage set with hot/cold water circulator 4VT)
• Software: Standard: Surface/Interfacial tension, Lamella length, Liquid density
• Detecting Parts: Standard: Platinum plate
• Option: Platinum ring, Pycnometer for density, Accessory for sedimentation
­• External Dimensions: 255(W)x307(D)x369(H) mm
• ­Weight: about 12.5kg
­• Electric power: AC100­240~50/60Hz 35W 75VA
16,000.00 16000.0 USD
Sale
Phoenix Smart (M)
Drop shape image analysis contact angle. Sessile drop method. Portable type, equivalent limitless sample size.
Manual drop control system.
- Max sample size: Equivalent with limitless
- USB 2.0 type Digital CCD camera, Frame rate: 70 frame/sec
- 640x 480 Pixel resolution
- Light source: LED
- Drop position checking window - Drop volume control by manual
- Able to touch to surface by manual control
- Contact angle measure range: 2 -180 degree,±0.1deg Accuracy
- Surfaceware9 Software for static, Surface energy, Surface tension by Pendent drop method, D-base, Data comparing, Auto avoid image noise of measuring, Exact drop volume calculator function, Analyzed data export to Excel, etc
- Standard supplied accessories: Syringe (3ml/10ea), Needle (30G,27G,22G:5/each), Manual, Calibration images(30, 120±0.5degree)
- Connect to Desktop PC or Laptop (Windows 7/8/10)
Device dimensions: 91mm(W) x 56mm(D) x 159mm(H)
11,167.00 11167.0 USD
Sale
DSR-500 Rheometer
DSR-500 Rheometer. Includes standard stand.
10,863.00 10863.0 USD
Sale
Automatic Tensiometer DST-60
Digital Tensiometer for DuNouy Ring and Wilhelmy Plate Methods. Includes customer's choice of Ring or Plate.
9,850.00 9850.0 USD
Sale
RM 200 Plus Rheometer
Viscosity range: 1 to 780,000,000 mPa.s
Includes Carry Case and Standard Stand.
FEATURES
• Ramp programming.
• Direct analysis with regressions.
• Direct control of temperature unit.
• Programming and recording method.
• Direct measure with time to stop.
• User and locked mode.
• Data recording and USB transfer.
• Torque gauge on display.
• Integrated temperature probe.
• Printer connection.
SPECIFICATIONS
• Type of instrument: Rotating springless rheometer with imposed speeds and 7’’ Touch screen
• Rotation speeds: Unlimited number of speeds between 0.3 and 1500 rpm
• Torque range: From 0.05 to 30 mNm
• Temperature: PT100 sensor indicates temperatures between -50 °C to + 300 °C
• Accuracy: +/- 1 % of the full scale
• Repeatability: +/- 0,2 %
• Display:
- Viscosity – Speed – Torque – Shear stress – Time –Temperature
- Choice of viscosity units: cP/Poises or mPa.s / Pa.s – Shear rate
• Security and confidentiality: An «operator» function allows you to enter a username for your instrument. This user must then be identified using a 4-digit code.
There is also a protected mode that locks your measurement conditions.
• Supply voltage: 90-240 VAC 50/60 Hz
• Analog output: 4 – 20 mA
• PC connections: RS232 Port and USB
• Printer connection
- USB Host Port
- Compatible PCL/5
REGULAR PRICE: $9,656.00
9,656.00 9656.0 USD
Sale
GT 300 Plus Gel Timer Viscometer
GT-300 Plus with No Temperature Control.
9,277.50 9277.5 USD
Sale
Sonic Sifter 220v 60Hz
Sonic Sifter Separator 220v 60Hz Designed for 3.5" (75mm) diameter acrylic-framed sieves and a patented oscillating air column allows this unit to achieve efficiencies previously seen only with wet sieving for materials in powdered, granular or pellet form ‰ÛÓ and is capable of achieving separations over the range of 3ë_m to 5.6mm.
8,543.00 8543.0 USD
Sale
Sonic Sifter 240V 50Hz
Sonic Sifter Separator 240V 50Hz
Specially designed 3-inch (75mm) diameter acrylic-framed sieves and a patented oscillating air column allow this unit to achieve efficiencies previously seen only with wet sieving for materials in powdered, granular or pellet form. Capable of achieving separations over the range of 3 microns to 5.6mm.
Unit Includes: Complete stack assembly and instruction manual. Sieves must be ordered separately.
8,543.00 8543.0 USD
Sale
Sonic Sifter
The Sonic Sifter Separator is designed for use with 3.5" (75mm) diameter acrylic-framed sieves. A patented oscillating air column allows this unit to achieve efficiencies previously seen only with wet sieving for materials in powdered, granular or pellet form. Capable of achieving separations ranging from 3 microns to 5.6mm.
Unit Includes: Complete stack assembly and instruction manual. Sieves must be ordered separately.
8,373.00 8373.0 USD
Sale
Air Sizer 200
Air Sizer 200 Sieve Shaker for 8” Premium air jet sieves 100-240 Volt 50-60Hz
8,283.00 8283.0 USD
Sale
Titan 450 Sieve Shaker, 230V 50Hz
Titan 450 Sieve Shaker, 230V / 50Hz
8,160.00 8160.0 USD
Sale
Titan 450 Sieve Shaker 110V 60Hz
Titan 450 Sieve Shaker 110/120 V, 60 Hz
8,160.00 8160.0 USD
Sale
Aquapal III Moisture Analyzer W/ Single-reagent Glassware
Coulometric Titrator Diaphragmless Glassware Tests according to ASTM D4928, D1533, D1744 and equivalent methods. CE approved manufacturer.
Unit ready for operation. Includes:
- Built in printer with standard paper that backs up test with hard copy results.
- Speed is 2 mg/minute
- Test range from 1ppm to 100%
- Sensitive to 0.1 ug
- Calculations in Weight, volume or dilution
- Automatic Drift Correction
- Results printed in ppm ,% , ug
- Standard RS232C output
- Small lab foot print 14" x 8"
- Portable (field Use)
- Easy to use for non-technical operators
- Simple keypad format with limited menus. Enter the weight or Specific gravity number, Press <ENTER>, Introduce sample, and press <START>. When the test finishes data showing the results will print out automatically.
7,900.00 7900.0 USD
Sale
Aquapal III Moisture Analyzer W/ Standard Glassware
Coulometric Titrator Standard Glassware Tests according to ASTM D4928, D1533, D1744, and equivalent methods. CE approved manufacturer.

Unit ready for operation includes:

- Built-in printer with standard paper that backs up a test with hard copy results.
- Verify test at any time with printout including mean, standard deviation and coefficient of variation.
- Speed is 2 mg/minute
- Test range from 1ppm to 100%
- Sensitive to 0.1ug
- Calculations in weight, volume or dilution
- Automatic Drift Correction
- Results printed in ppm, %, ug
- Standard RS232C output
- Small lab foot print 14" x 8"
- Portable (field use)
7,900.00 7900.0 USD
Sale
Digital Tensiometer DST-30
Digital Tensiometer for DuNouy Ring and Wilhelmy Plate Methods. Includes customer's choice of Ring or Plate.
7,500.00 7500.0 USD
Sale
Portable RM 100 Viscometer with Carrying Case
VISCOSITY RANGE: 200 to 240 million mPa.s (with MS ASTM R2 to R7, not included)
Features:
- Autonomy more than one hour.
- Charge indicator.
- Direct measure with time to stop.
- Data recording and USB transfer.
- Torque gage on display.
- Usable with standard stand.
- Huge viscosity range.
- Programming and recording method.
- User and locked mode.
- Integrated temperature probe.
- Printer connection.
- Compatible with RheoTex software.
SPECIFICATIONS
Type: Rotating springless viscometer with 7’’ Touch screen
Rotation speeds: Unlimited number of speeds between 0.3 and 1500 rpm
Torque range: From 0.05 to 30 mNm
Temperature: PT100 sensor indicates temperatures from -50 °C to + 300 °C
Accuracy: +/- 1% of the full scale
Repeatability: +/- 0,2%
Display: Viscosity – Speed – Torque – Shear stress – Temperature – Shear rate –
Choice of viscosity units: cP/Poises or mPa.s / Pa.s – Charge level indication
Compatible measuring system: MS DIN, MS ASTM, MS BV, MS VANE, MS R, MS ULV, MS SV
Compatible temperature control: EVA DIN, EVA MS-R, EVA LR-BV, RT1
Supply voltage: 90-240 VAC 50/60 Hz
Analog output: 4 – 20 mA
PC connections: RS232 Port and USB
Printer connection: USB Host Port - Compatible PCL/5

REGULAR PRICE: $7,452.00
7,452.00 7452.0 USD